P a g e 7
A X 2 0 0 S t a n d a r d C o n n e c t i o n D i a g r a m
2
2
Normally Closed Door
Contact
Normally Open REX
Button
0 V DC
+12 V DC
Double pole
Breakglass
Magnet Lock
Normally Open REX
Button
0 V DC
+12 V DC
Normally Closed Door
Contact
Double pole
Breakglass
Magnet Lock
0 V DC
+12 V DC
Fire Alarm System Relay
Normally Closed
(Voltage Free)
Fire Alarm
Normally Closed
12 V DC Power
+12 V DC
0 V DC
+12 V DC
0 V DC
+12 V DC
0 V DC
+12 V DC
0 V DC
Ethernet Hub / Lan / Wan RJ45 Network
connection
+
-
+
-
Screen
Screen
Cable Specifications
Description
Cable Type
Maximum Length
AX200 Ethernet
Connection 10 mbs
Cat 5 / Cat 5E
100/185 metres
AX200 to AX100
RS232
4 Core Screened
2 x 2 x 22AWG
15 metres
AX100 to AX Reader
6 Core 7-2-6C
Def Stan 61-12
unscreened
50 metres
AX100 to REX/Door
Contact
2 Core 24 AWG
unscreened
50 metres
AX100 to Lock
2 Core
> 24 AWG
unscreened
50 metres
Power Specifications
Description
Voltage
Current
AX100
12 volt DC
45 mA
AX200
12 volt DC
250 mA
AX Proximity Reader
12 volt DC
45 mA
A single 12 volt DC power supply may be used >500 mA
Typical Power supply including 2 Magnet locks 1.4 Amp
AX200 Network Controller
AX200 LED Status (Front Panel)
Blue
ON = Processor OK & Power OK
Red
ON = Fire Alarm
Flashing = Breakglass Alarm
OFF = Fire alarm OK & Breakglass OK
21
Green
ON = AX100 door Interface connected
Green
ON = Online to PC
ON for 15 seconds = Not configured
OFF= Offline / Not configured
Amber
ON = Ethernet Link indication
OFF = Ethernet link incorrect or missing
connection (Check network cable)
RS485
RX
TX
Amber
RS485 Communication AX150
Factory
Reset
21
Green
Press and hold the reset switch and apply
power. The LED’s will alternate flashing every
0.5 seconds to indicate the unit has been reset.
Release the reset switch and re-apply power.
AX200 Standard 7 August 2007 (V9)
AX200
Standard Connection
Fire Alarm
Normally
Closed
+
-
Breakglass
Door 1
OUT
Breakglass
Door 2
IN
AX100
OUT
Device 1
3 2
GND
3 2
GND
AX100
IN
Device 2
AX200
RS485
1 2
Screen
NC NCC C
J1 Expansion Bus
Breakglass
Relay Outputs
LED
LED Indicator
Green = OK
Red = Reversed
polarity
Orange = Incorrect PSU
To reset the electronic
fuse, disconnect the
power, wait 30 seconds
and then reconnect the
power.
NO NO
Power
In
12VDC
Green LED
Link cable
Orange LED
activity
Relays
volt-free contacts
Max. 5Ah at
12VDC
Door 1 Door 2
NC C NO
Access Granted
Door 1 & 2
Pulse 1 second
35 5
POWER
OUT
12vDC
EOL RS485
AX200-0306
RJ45 Network
OFF
PSU
Monitoring
Volt Free NC
+
-
+12V 0V
C NC2A 2A3A 3A
3
Sounder
Reset
Switch
! Note A diode
must be fitted to
prevent back EMF
unless the lock has
a factory fitted
diode.
! Note A diode
must be fitted to
prevent Back EMF
unless the lock has
a factory fitted
diode.
Expander Board
max.
100 mA
+12VDC Out
Output 4
Output 5
Input 4
Input 5
- Power Out
DC Voltage Only
Green = Power OK
Red = wires reversed, re-wire
Orange = AC voltage, change
PSU
To reset the electronic fuse,
disconnect the power, wait 30
seconds and then reconnect the
power.
Reader wiring connections
shown are for standard AXP
readers.
Reader
White
Red
Black
0V LED D1 D0 +12V
Door
C'tct
C REX 0V +12V
Power In
DC
>65mA
Blue &
Yellow
NO
NC
C
Lock Relay
Green
3 2 5
N/A
0V
TX
RX
RS232 to PC for
standalone
AX100
max. 15
metres
AX200
AX100
Door
Interface
DC Voltage Only
Green = Power OK
Red = wires reversed, re-wire
Orange = AC voltage, change
PSU
To reset the electronic fuse,
disconnect the power, wait 30
seconds and then reconnect the
power.
Reader wiring connections
shown are for standard AXP
readers.
Reader
White
Red
Black
0V LED D1 D0 +12V
Door
C'tct
C REX 0V +12V
Power In
DC
>65mA
Blue &
Yellow
NO
NC
C
Lock Relay
Green
3 2 5
N/A
0V
TX
RX
RS232 to PC for
standalone
AX100
max. 15
metres
AX200
AX100
Door
Interface
Power In
Power In
Power In
Power In
Power In
2A
3A
2A
3A
Power Out Connection.
Maximum output = 300mA
Suitable for AX100 and Reader.
Do not use for lock supply.